Reference

Server

Starts a run when the server starts, stops or crashes.

Category
Trigger
Topics
Scheduler
01

Ports

Servertrigger
  • Cooldownnumber
  • onCompletecontrol
Ports Control Data
Data types string number bool

Strings accept any data input.
Numbers accept boolean input.

02

Fields

Field What it does Default Limits
Type The server event that fires the block. Stopped
  • Stopped
  • Started
  • Crashed
Cooldown (seconds) The shortest time between two firings of this block. 300 0 s or more. A negative or empty value uses 300 s.
03

What a run does

Started fires when Konnekt launches the server process, before the server has finished loading.
Stopped fires when the process exits after a deliberate stop, from Konnekt or from the server itself.
Crashed fires when it exits any other way, or after the server logged a crash.

The run starts at this block and leaves by onComplete.
The block has no data outputs.
A restart from Konnekt fires Stopped, then Started.

The cooldown counts per block.
A value wired into Cooldown is not read.
It fires only for the server the graph belongs to.